Brand Name : Sinuo
Model Number : SNQC1006
Certification : Calibration Certificate (Cost Additional)
Place of Origin : China
MOQ : 1
Price : Customized
Payment Terms : L/C, T/T
Supply Ability : 20 Sets Per Month
Delivery Time : 30 Days
Packaging Details : Plywood
Temperature Measurement Range : 0~400°C
Applied Standard : IEC62196-1:2014 IEC60309-1:2012
Output Voltage : AC 5V
Temperature data recording : By computer or U disk storage
Output Current : Max. 400.0A
Test Content : Temperature rise
Test Channels : 8 channels
8 channels : PLC
IEC60309-1 2012 8 Channels Connector Temperature Rise 0 To 400°C Test System
Equipment Overview:
The equipment provides a low voltage test voltage to the sample by simulating the normal use environment, and collects the temperature rise within a certain period of time and compares it with the standard requirements.
It is used for testing the temperature rise of plugs and sockets of charging ports interface after passing the rated current, assessing the heating of the surface of the electrical accessories when the load current is switched on and whether the temperature rise of the terminals complies with the standard requirements.
Can be used to test electric vehicle charging ports, industrial plugs and sockets and couplers.
Structures & Characteristics:
The temperature rise test system consists of a voltage regulator, a current transmitter, a PLC programmable controller, a current transducer, a touch-type human-machine interface and a movable chassis. It can stabilise the output test current, eliminating the effects on the test current due to fluctuations in the supply voltage, changes in the resistance of the connecting wires or copper rods or test samples, and improving the accuracy of the test results. The power supply has the advantages of low loss, high efficiency, easy operation, and complete control and detection functions. The touch screen displays the current value and temperature value of each temperature measurement point at any time. Temperature values are recorded every 2 seconds and a report is generated, which can be stored on a USB stick or copied to a PC for viewing and printing.
Technical Parameters:
Temperature Measurement Point | 8 channels |
Operation Method | Color humanized touch interface |
Output Constant Adjustable Current | AC 0.50~50.00~400.0A(Level 1, can be set) |
Output Current Mode | Continuous/ Intermittent |
Load Test Output Voltage | Below AC 5V |
Current Resolution | 0.1A |
Ammeter Accuracy | ±1%±3 bytes |
Voltmeter Accuracy | ±1%±3 bytes |
Continuous Mode Test Time | 0.01~99.99 hours |
Intermittent Mode Test Time | 0.01~99.99 hours |
Intermittent Mode Test Cycles | 1~99999 cycles, automatic shutdown when the test cycles reach to the preset value |
Temperature Measurement Range | 0~400°C, accuracy 0.3% reading + 1°C; resolution: 0.1°C |
Temperature Data Acquisition | Configure RS232 communication interface and data record interface |
Temperature Scanning Speed | 1 to 255 seconds all channels |
Temperature Data Record | The data can be stored U disk |
Temperature Measuring Thermocouple | OMEGA USA Model T 30AWG Filament Thermocouple, 2 Metres, 8 pcs. |
Power Supply | Single phase AC220V±10%, 50/60Hz, 3KVA |
Equipment Dimensions and weight | Approx. L 800mm* W 680mm* H1610mm, 125KG |
![]() |
IEC60309-1 2012 Vehicle Testing Equipment 8 Channels Connector Temperature Rise 0 To 400°C Test System Images |