Brand Name : Sinuo
Model Number : SN771A
Certification : Calibration Certificate (Cost Additional)
Place of Origin : China
MOQ : 1
Price : Negotiable
Payment Terms : T/T, L/C, Western Union, MoneyGram
Supply Ability : 10 Sets Per Month
Delivery Time : 30 Days
Packaging Details : Plywood
Applied Standard : IEC60695-11-20 & IEC60695-11-4
Burning time : 0-9999X0.1S,it can be preseted
Residual flame/residual burning time : 0-9999X0.1S,it can be displayed
Flame height : 50w: 20±2mm 500w: 40±2mm
Control Mode : Touch screen
Heating time : 50w: 44±2S 500w: 54±2S
IEC60695-11-20 Horizontal & vertical combustion Flammability tester
Product:
Horizontal vertical combustion tester conforms to the standard of IEC60695-11-10, IEC60695-11-20 and IEC60695-11-4.
This equipment is used to simulate the early stage flame influence in the event of fire around electrical and electronic products, so as to assess the fire hazard degree by simulation technology. It is mainly used for horizontal and vertical flammability test of relative combustion characteristics of plastic and other non-metallic material parts samples, solid materials and foam plastics whose density is not less than 250kg/m' according to the method of ISO845.
Equipment advantages:
This series of products adopt integral intake automatic ignition system, the combustion delay is only 0.1 seconds, to ensure the full combustion of gas; Adopt steel structure box, the inner box is black matte light background, large observation window, imported high precision digital display instrument, accurate detection.
Controlled by touch screen, the test is accurate and efficient.
Technical parameters:
Parameter/ model | SN771A |
Operation | Touch screen operation, with infrared remote control |
Control | Advanced PLC |
Display | 7 inch color touch screen |
Torch standard | Iec60695-11-3 /IEC60695-11-4/10,UL94, inner diameter φ 9.5±0.3mm, length 100mm, made of brass |
gas pressure | 0.1MPa |
Gas flow | 50W: 105±5ml/min or 18±1 mm; 500W: 965±30ml/min or 117±3 mm, flow meter adjustment |
U-shaped pressure gauge back pressure water column height | 50W: 10mm; 500W: 125±5 mm |
Test angle | 50W: 0°,45°; 500W: 20° |
Burning time | 0-9999X0.1S can be preset |
Number of burns | 0-9999 times, can be preset |
After flame/after burning time | 0-9999X0.1S can be displayed |
![]() |