IEC 61000-4-6 EMC Conducted RF Immunity And BCI Test System

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

IEC 61000-4-6 EMC Conducted RF Immunity And BCI Test System

  • 1
  • 2
  • 3

Brand Name : Sinuo

Model Number : SN6618

Certification : Calibration Certificate (Cost Additional)

Place of Origin : China

MOQ : 1

Price : Customized

Payment Terms : L/C, , T/T, Western Union, MoneyGram

Supply Ability : 10 set per month

Delivery Time : 30 Days

Packaging Details : Plywood

Applied Standard : IEC 61000-4-6 & ISO 11452-4

Test Content : Conducted RF Immunity Test

Signal Generator Frequency Range : 9 kHz ~ 1 GHz

Power Amplifier Frequency Range : 100kHz ~ 400MHz

RF Power Meter : 9kHz-3GHz

EM Injection Clamps : 10kHz - 1GHz

Aadapter : 50/150 Ohm adapter

50 Ohm : 50 Ohm closing

Contact Now

IEC 61000-4-6 and ISO 11452-4 Conducted RF Immunity Test System

System configuration:

Conducted RF immunity test system and BCI test

Lower test equipment wavelength (the EUT) than the size of the frequency (e.g., 80MHz or less) much less interference wave, in contrast, leads apparatus (including power lines and the overhead lines extend, a communication line interface length of cable, etc.) is an interference wave may reach several wavelengths or longer. Apparatus becomes the passive antenna lead, susceptible to interference from RF fields induced near field electromagnetic RF voltage and current ultimately affect device formation.

The bulk current injection (BCI) test method is based on current injection into the wiring harness using a current probe as a transformer where the harness forms the secondary winding.

Technical parameters:

Model and Name Basic parameters Quantity
Signal generator Frequency range: 9 kHz ~ 1 GHz 1
Power Amplifier Frequency range: 100kHz ~ 400MHz; Output Power: 100W 1
CDN M2 M2 ,32A CDN network and its calibration kit, attenuators, 1
CDN M3 M3,32A CDN network and its calibration kit, attenuators, 1
RF Power Meter RF power meter: 9kHz-3GHz 3
EM Injection Clamps

10kHz - 1GHz: 100 watts COUPLING APERTURE 23mm

Include: calibration fixture

1
Aadapter 50/150 Ohm adapter 2
50 Ohm 50 Ohm closing 1
ATT 6 dB, 60 W damper 1
Bulk Current Injection 10 kHz - 400 MHz 100W inner diameter 1
Calibration Fixtures Calibration Fixtures for Bulk Current Injection 1
CURRENT PROBE

Frequency: 10 kHz – 400 MHz

Internal diameter: 40 mm

1
Test software Automatic calibration radiated immunity test software, compliance with IEC61000-4-6, ISO11452-4 1
System integration Systems design, integration, project management, factory acceptance, site installation, commissioning and training 1
Includingfollowing accessories for IEC 61000-4-6 measurements:

- M2+3 connection network

- EM clamp for connecting to an at least 20 mm diameter cable

- The calibration accessories of the EM clamp (calibration fixture)

- 50/150 Ohm adapter (2 pcs)

- 50 Ohm closing

- 6 dB, at least 60 W damper

- current measuring ring for the control measurement

- the necessary connecting RF cables for all the above mentioned.

Test Conducted RF immunity schematic


Product Tags:

IEC 61000-4-6 BCI Test System

      

EMC BCI Test System

      

400MHz EMC Test Equipment

      
Quality IEC 61000-4-6 EMC Conducted RF Immunity And BCI Test System for sale

IEC 61000-4-6 EMC Conducted RF Immunity And BCI Test System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)